Interpretation guide: SINGLE BAND tests: Difference between revisions
From MalariaETC
No edit summary |
No edit summary |
||
| Line 26: | Line 26: | ||
<span style="font-size:90%">The test has '''valid control line''' (black arrow) and an '''additional band in the species-specific area''' (red arrow)</span> | <span style="font-size:90%">The test has '''valid control line''' (black arrow) and an '''additional band in the species-specific area''' (red arrow)</span> | ||
<gallery mode="nolines" widths=100px heights=200px> | <gallery mode="nolines" widths=100px heights=200px> | ||
File: | File:RDT single two band+.jpg|<span style="font-size:90%"></span>|link={{filepath:RDT single two band+.jpg}} | ||
</gallery> | </gallery> | ||
<span style="font-size:90%">'''Most likely interpretation:''' The species detected by the test is present and is the only malaria species infecting the individual</br></span> | <span style="font-size:90%">'''Most likely interpretation:''' The species detected by the test is present and is the only malaria species infecting the individual</br></span> | ||
Revision as of 10:07, 24 September 2024
Navigation
Go Back
| RESULT PATTERN 1
|
No band appears in the control area (black arrow)
Irrespective of whether any other bands are present, this is always an invalid test: do not interpret. Report as failed test
Action:
- Repeat the test
- Consider the reasons for [ test failure ]
| RESULT PATTERN 2 |
The test has valid control line (black arrow) and an additional band in the species-specific area (red arrow)
Most likely interpretation: The species detected by the test is present and is the only malaria species infecting the individual
Less common but possible interpretations:
- There is a dual-species infection (a second species cannot be detected by single band kits)
- The patient recently received successful treatment, but the antigen has not yet cleared
- The "specific band" is a false positive result (infrequent but observed)
| RESULT PATTERN 3 |
The test has valid control line (black arrow) but there is no band in the species-specific area (red arrow)
Most likely interpretation: the species detected by the test is not present
Possible alternatives:
- A faint band was present but not seen by observer*
- The species is present but not detected due to low parasite concentration (link to reasons)
- The species is present is but not detected for technical reasons
- The species is present, but there is gene deletion of the target antigen (HRP2 tests)
- The species is present but exceeds test capacity due to very high parasite Pyrome effect (mainly HRP2 tests)