Actions

General and specific limitations of RDT tests: Difference between revisions

From MalariaETC

(Created page with "In the case of malarial RDTs, the WHO requires a panel detection score of 75% at a parasitaemia of 200 parasites/μl in order for the product to warrant endorsement. [16] However, the threshold for pyrogenic onset has been shown to vary from 10 to 200,000 parasites/μl, with 22% of patients developing their first acute fever at a parasite load below 200/μl. [75] Thus, even for the select assortment of commercial malaria RDTs demonstrating compliance with WHO standards,...")
 
No edit summary
Line 1: Line 1:
----
'''Navigation'''</br>
[[Rapid diagnostic tests (RDTs)|Go Back]]
----
{| class="wikitable" style="widthe:90%; border-style: solid; border-width: 4px; color:black"
|colspan="1" style = "font-size:100%; color:blasck; background: FFFAFA"|<span style="color:navy>'''Practical considerations '''</span>
In the case of malarial RDTs, the WHO requires a panel detection score of 75% at a parasitaemia of 200 parasites/μl in order for the product to warrant endorsement. [16] However, the threshold for pyrogenic onset has been shown to vary from 10 to 200,000 parasites/μl, with 22% of patients developing their first acute fever at a parasite load below 200/μl. [75] Thus, even for the select assortment of commercial malaria RDTs demonstrating compliance with WHO standards, sufficiently low limits of detection have not been demonstrated for the early and accurate diagnosis of nascent infections, or of asymptomatic carriers.
In the case of malarial RDTs, the WHO requires a panel detection score of 75% at a parasitaemia of 200 parasites/μl in order for the product to warrant endorsement. [16] However, the threshold for pyrogenic onset has been shown to vary from 10 to 200,000 parasites/μl, with 22% of patients developing their first acute fever at a parasite load below 200/μl. [75] Thus, even for the select assortment of commercial malaria RDTs demonstrating compliance with WHO standards, sufficiently low limits of detection have not been demonstrated for the early and accurate diagnosis of nascent infections, or of asymptomatic carriers.

Revision as of 14:12, 13 September 2024


Navigation
Go Back



Practical considerations

In the case of malarial RDTs, the WHO requires a panel detection score of 75% at a parasitaemia of 200 parasites/μl in order for the product to warrant endorsement. [16] However, the threshold for pyrogenic onset has been shown to vary from 10 to 200,000 parasites/μl, with 22% of patients developing their first acute fever at a parasite load below 200/μl. [75] Thus, even for the select assortment of commercial malaria RDTs demonstrating compliance with WHO standards, sufficiently low limits of detection have not been demonstrated for the early and accurate diagnosis of nascent infections, or of asymptomatic carriers.